Kit Lev'O + LPG Level

Presentation


The Kit Toran'O - Lev'O+ - LPG Liquid is a bundle compatible with the Toran'O device.

Family code

The family code of Kit Toran'O - Lev'O+ - LPG Liquid device is: 50-70-210-(000 and upper) or 50-70-211-(000 and upper)

User guide

Installation and operation


Installation

Radio propagation

see Toran'O

Autonomy


see Toran'O

Human Machine Interface


see Toran'O

Applicative layer


Codecs are available to decode frames: Downloads

Encoder are available on Online Codec

The external sensor is ratio metric. The result  is done in pourcent. It is necessary to convert in Voltage then use this table to finally convert in pourcent of filling of tank.

The formule to use is :

VoltageOutput  =  Measured_Value * 5 /100                    [Volt]

then use this table:

ex: Measured_Value = 78.12% => Measured_Value = (78.12 * 5 ) / 100 = 3.906 V. The corresponding graduation is 80%. So the filling of the tank is 80 %.

Default configuration

A default configuration is set:

  • The device reports:
    • ...

Every change made to the default configuration must comply with the legal duty cycle (for example, the most restrictive in the EU is 0.1%, which corresponds to approximately 1 frame per hour with SF12)

Frame examples


see Toran'O