Kit Lev'O + LPG Level
Presentation
The Kit Toran'O - Lev'O+ - LPG Liquid is a bundle compatible with the Toran'O device.
Family code
The family code of Kit Toran'O - Lev'O+ - LPG Liquid device is: 50-70-210-(000 and upper) or 50-70-211-(000 and upper)
User guide
Installation and operation
Installation
Radio propagation
see Toran'O
Autonomy
see Toran'O
Human Machine Interface
see Toran'O
Applicative layer
Codecs are available to decode frames: Downloads
Encoder are available on Online Codec
The external sensor is ratio metric. The result is done in pourcent. It is necessary to convert in Voltage then use this table to finally convert in pourcent of filling of tank.
The formule to use is :
VoltageOutput = Measured_Value * 5 /100 [Volt]
then use this table:
ex: Measured_Value = 78.12% => Measured_Value = (78.12 * 5 ) / 100 = 3.906 V. The corresponding graduation is 80%. So the filling of the tank is 80 %.
Default configuration
A default configuration is set:
- The device reports:
- ...
Every change made to the default configuration must comply with the legal duty cycle (for example, the most restrictive in the EU is 0.1%, which corresponds to approximately 1 frame per hour with SF12)
Frame examples
see Toran'O